Force modelsim user manual

Modelsim users manual this document is for information and instruction purposes. Ermoglicht im fenster force selected signal siehe darunter im feld value eine. If this screen is not available, you can display it by selecting help welcome. The operating system support pages include release notes that describe known issues in the modelsim altera software.

Installation instructions for modelsimaltera software. Create a do file that will add signals to the wave window, force signals, and run the. Mentor graphics reserves the right to make changes in specifications and other information contained in this publication without prior notice, and the reader should, in all cases, consult mentor graphics to determine whether any changes have been made. Since force commands like all commands can be included in a macro file, it is possible to create complex sequences of stimuli. The software installation directory path must not contain spaces. The modelsim debug environment efficiently displays design data for analysis and debug of all languages. For more information about using project files, see the modelsim users manual.

Find modelsim training at mentor graphics training centers around the world or at your site. The graphical user interface is powerful, consistent, and intuitive. Modelsims awardwinning single kernel simulator sks technology enables transparent mixing of vhdl and verilog in one design. Modelsim intel fpga edition installation instructions formerly altera pc installation. Follow the onscreen instructions to install the software. In modelsim, go to help documentation pdf bookcase, then open the command reference manual. Click in the waveform window to enable the wave menu. Oct 19, 20 this video shows how to force a value to input in modelsim. If you then change cd to another directory that contains a different i file with a transcriptfile variable setting, the simulator continues to save to the original transcript file in the former location. I want to be able to set the filename from the outside. See creating a vcd file and using extended vcd as stimulus. It is divided into fourtopics, which you will learn more about in subsequent. You can consult the modelsim users manual to get a description of each. On the wave menu, point to mouse mode and then click edit mode.

The cdbg command provides commandline equivalents of the menu options that are. The default behavior is that modelsim uses its own internal editor, which i dont like. Modelsim eases the process of finding design defects with an intelligently engineered debug environment. Modelsim tutorial pdf, html select help documentation. File and directory pathnames several modelsim commands have arguments that point to files or directories. Its architecture allows platformindependent compile with the outstanding performance of native compiled code. This document is for information and instruction purposes. In the modelsimaltera software, on the help menu, point to pdf documentation, and then click users manual. Modelsim users manual pdf, html select help documentation modelsim command reference pdf, html select help documentation modelsim gui reference pdf, html select help documentation foreign language interface reference.

In mapping, modelsim copies a file called modelsim. I think your force command is not using the correct syntax. This lesson provides a brief conceptual overview of the modelsim simulation environment. Unauthorized copying, duplication, or other reproduction is prohibited without the written consent of model technology. Modifying stimulus waveforms to modify stimulus waveforms, follow these steps. The information in this manual is subject to change without notice and does not. If you set the editor environment variable, the tcl edit command will use your editor. As im using modelsim altera starter edition to simulate my design, it should be possible to set the string containing the filename over a force command or similar. You can force virtual signals um248 if the number of bits corresponds to the signal.

The information in this manual is subject to change without notice and does not represent a commitment on the part of model technology. Note neither the prompt at the beginning of a line nor the key that ends a line is shown in the command examples. Read optimizing designs with vopt in the users manual for. When you invoke vsim using the default modelsimini file a. Modelsim users manual modelsim is produced by model technology incorporated. The questa advanced simulator combines high performance and capacity simulation with unified advanced debug and functional coverage capabilities for the most complete native support of verilog, systemverilog, vhdl, systemc, sva, upf and uvm. Mentor graphics reserves the right to make changes in specifications and other information contained in this publication without prior notice, and the.

241 863 917 597 591 48 132 724 969 1531 84 439 654 55 1311 211 549 994 799 1038 1512 57 1493 1129 1415 1400 695 1288 91 300 380 829 925 1192 703 1452 592 1136 541 107 1273